Products

Static UPS range

Static UPS: static Uninterruptible Power Supplies

The ABB static UPS offer consists of a complete range of UPS in standard or modular formats:

  • single-phase unit power of 0.35 kVA to 10 kVA
  • three-phase unit power of 10 kVA to 1,500 kVA

Energy can be stored in batteries (VRLA, NiCd or Li-Ion, depending on the model).

Please contact our staff for other powers or information about the accessories for static UPS.

Find out more about our product range

Filter by type of UPS
UPS Type (trad)
Filter by power
UPS Power

PV11 TG2 series from 1 to 10 kVA

Single-phase/Single-phase UPS – On-line double conversion
Key features of the UPS:
  • Range: 1-2-3-6-10 kVA
  • Output power factor: 0.9
  • Yield (100% of load): up to 94.2%
  • Eco-yield: up to 98%
  • Input Thdi:  <5% to 100% of load
  • Parallel: x3 only 6-10 kVA
  • Internal maintenance bypass
  • MODBUS and SNMP communication interfaces

PV11RTG2 series from 1 to 10 kVA

Single-phase/Single-phase UPS – On-line double conversion
Key features of the UPS:
  • Range: 1-2-3-6-10 kVA
  • Output power factor: 0.9
  • Yield (100% of load): up to 94.2%
  • Eco-yield: up to 98%
  • Input Thdi:  <5% to 100% of load
  • Parallel: x3 only 6-10 kVA
  • External maintenance bypass
  • 19-Inch RACK unit
  • MODBUS and SNMP communication interfaces

PV11-31 T series from 10 to 20 kVA

Three-phase/Single-phase UPS – On-line double conversion
Key features of the UPS:
  • Range: 10 or 20 kVA
  • Input 3 ph+N / Output 1 Ph+N
  • Output power factor: 0.9
  • Yield (100% of load): 93%
  • Eco-yield: up to 98%
  • Input Thdi:  <5% to 100% of load
  • Parallel: x4
  • Internal maintenance bypass
  • MODBUS and SNMP communication interfaces

SG PurePulse Series / 10 to 40kVA

Three-phase/Three-phase UPS – On-line double conversion – With output isolation transformer
Key features of the UPS:
  • Range : 10-15-20-30-40 kVA
  • Output power factor: 1
  • Yield (100% of load): 94%
  • Eco-yield: up to 98%
  • Input Thdi:  <2% to 100% of load
  • Parallel: x6
  • Internal maintenance bypass
  • Triangular/star output isolation transformer
  • MODBUS and SNMP communication interfaces

PSC33 Series / 10 to 50 kVA

Three-phase/Three-phase UPS – On-line double conversion
Key features of the UPS:
  • Range: 10-15-20-25-30-40-50 kVA
  • Output power factor: 0.9
  • Yield (100% of load): 95.5%
  • Eco-yield: up to 98%
  • Input Thdi: <3% to 100% of load
  • Parallel: x20
  • Internal maintenance bypass
  • MODBUS and SNMP communication interfaces

DPA UPSCALE ST S2 Series / 10 to 200 kVA

Three-phase/Three-phase Modular UPS – On-line double conversion
Key features of the UPS:
  • Range: 10 to 200 kVA
  • Frame: 40-60-80-120-200 KW
  • Output power factor: 1
  • Power module: 10 or 20 kW rackable when hot
  • N+1 redundancy possible
  • Yield (100% of load): 96%
  • Eco-yield: up to 98%
  • Parallel: up to 20 modules (400 kW max.)
  • Input Thdi:  <3% to 100% of load
  • Reduced space requirement (0.42m2)
  • MODBUS and SNMP communication interfaces

DPA S4 Series / 50 to 300 kVA

Three-phase/Three-phase modular UPS - On-line double conversion
Key features of the UPS:
  • Range:50 to 300 kVA
  • Frame: 300 kW (6 modules or 5 N+1)
  • Output power factor: 1
  • Power module: 50 kW rackable when hot
  • Parallel: x6 (1500 kW)
  • Yield (100%): 97.4%
  • Eco-yield: up to 99%
  • Input Thdi:  <3% to 100% of load
  • Reduced space requirement (0.75m2 on ground)
  • MODBUS and SNMP communication interfaces

PW33 Series / 60 to 500 kVA

Three-phase/Three-phase UPS – On-line double conversion
Key features of the UPS:
  • Range: 60-80-100-120-160-200-250- 300-400-500 kVA
  • Output power factor: 1
  • Yield (100% of load): 95.5%
  • Eco-yield: up to 99%
  • Input Thdi:  <3.5% to 100% of load
  • Parallel: x10
  • Internal maintenance bypass
  • MODBUS and SNMP communication interfaces

DPA 500 Series / 100 to 500 kVA

Three-phase/Three-phase modular UPS - On-line double conversion
Key features of the UPS:
  • Range: 100 to 500 kVA
  • Frame: 500 kW (5 modules or 4 N+1)
  • Output power factor: 1
  • Power module: 100 kW rackable when hot
  • Parallel: x6 (3,000 kW)
  • Yield (100%): 96%
  • Eco-yield: up to 99%
  • Input Thdi:  <3.5% to 100% of load
  • Reduced space requirement (1.5m2 on ground)
  • MODBUS and SNMP communication interfaces

SG PurePulse Series / 60 to 500kVA

Three-phase/Three-phase UPS – On-line double conversion – With output isolation transformer
Key features of the UPS:
  • Range : 60-80-80-100-120-160-200-300-400-500 kVA
  • Output power factor: 0.9
  • Yield (100% of load): 94%
  • Eco-yield: up to 98%
  • Input Thdi:  <2% to 100% of load
  • Parallel: x6
  • Internal maintenance bypass
  • Triangular/star output isolation transformer
  • MODBUS and SNMP communication interfaces

TLE Series / 160 to 800 kVA

Three-phase/Three-phase UPS – On-line double conversion
Key features of the UPS:
  • Range: 160-200-320-400-600 -800 kVA
  • Output power factor: 1
  • Yield (100% of load): 96.7%
  • Eco-yield: up to 99%
  • Input Thdi:  <3% to 100% of load
  • Parallel: x6
  • Internal maintenance bypass
  • No load-based decommissioning up to cos Phi 0.8 Capacity
  • MODBUS and SNMP communication interfaces

MEGAFLEX Series / 250 to 1,500 kVA

Three-phase/Three-phase modular UPS - On-line double conversion
Key features of the UPS:
  • Range: 250 to 1,500 kVA
  • Frame: 1,000 kW (4 modules) or 1,500 kW (6 modules) – N+1 redundancy possible
  • Output power factor: 1
  • Power module: 250 kW rackable when hot
  • Parallel: x4 (6,000 kW)
  • Yield (100%): 97.2%
  • Eco-yield: up to 99%
  • Input Thdi:  <4% to 100% of load
  • Reduced space requirement (3 m2 on ground 1,500 kW)
  • MODBUS and SNMP communication interfaces